American Chillers and Cooling Tower Systems

Manufacturer of industrial process chillers
for medical, dry cleaning, aerospace,
food processing and more...

More about us >>

Posts From Kenneth Schaafsma

Used Process Chillers For Sale

Used Process Chillers For Sale

Uncategorized 🕔January 2, 2015

Used Process American Chiller For Sale. $13,589.00 (List price is $43,745.00) 15 hp, Low Temperature Chiller, recirculating with Tank and pump, Copeland semi hermetic compressor, 460/3/60, FLA 34.5. New in 2012 with very little run time. Told it was used

Read More

Long time customer Bob Ferber picking up his 7.5 ton American Chiller

Dry Cleaning Chillers 🕔December 10, 2014

Bob Ferber recently paid a visit to American Chillers to pick up a 7.5 ton horizontal chiller for a rooftop installation at a dry cleaning plant in New Jersey. Bob has been a loyal American Chillers customer since the 1980′s.

Read More
American Chillers Cold Plunge Chiller – NBA Thunder

American Chillers Cold Plunge Chiller – NBA Thunder

Cold Plunge Chiller 🕔November 15, 2014

The Oklahoma City Thunder professional basketball team recently turned to American Chillers & Cooling Tower Systems, Inc. for their therapy cold plunge pool chiller. The team at American Chillers have been providing chillers for professional sports teams since the 1980′s.

Read More

4 TON (208-230/3/60) BREWERY CHILLER SPECIFICATION

Brewery Chillers 🕔September 15, 2014

Information provided is subject to change at manufacturers discretion. Submittals available upon request with purchase order.

Read More

What pipe size should I use for my chiller or cooling tower system?

Uncategorized 🕔July 18, 2014

What pipe size should you use for your chiller or cooling tower? A common technical support issue has to do with properly or improperly sizing piping runs. When in doubt, call the factory for assistance. However, a couple of quick

Read More

Having Chiller Problems?

Uncategorized 🕔July 9, 2014

5 Things to check before calling chiller technical support. Check the flow rate. Most chillers are set up to run approximately 2.4 GPM / ton. If you don’t have a flow meter installed (and you have a small chiller) you

Read More

Glycol – Not just for cold weather anymore

Uncategorized 🕔January 16, 2014

Glycol or anti-freeze is a given in cold weather to prevent frozen pipes and chiller damage, but using glycol will also help to keep your system in proper working condition for many years to come.   DON’T USE THESE GLYCOLS

Read More

R22 – Still Available!

Uncategorized 🕔January 16, 2014

R-22 refrigerant is alive and well. The installed customer base in both air conditioning and commercial equipment is so huge that even though the manufacture of R-22 is banned, the world is flooded with R-22, and modern methods of recovery

Read More