American Chillers and Cooling Tower Systems

Manufacturer of industrial process chillers
for medical, dry cleaning, aerospace,
food processing and more...

More about us >>

COLD PLUNGE & SPA CHILLERS

Cooling for cold plunge pools, spas and therapy pools. American Chillers engineers have built cold plunge pool chillers for 30 years.

You Provide the Pool, We Supply the Chiller!
Our experience includes customers like The Oklahoma Thunder, Philadelphia 76ers, Chicago Bears, Denver Nuggets and LA Mighty Ducks plus numerous health clubs, therapy centers, cruise ships and more. Engineering for unique pool applications is our specialty. We can build for salt water pools, fresh water or chlorine. Please specify which type of pool when ordering.

AMERICAN COLD PLUNGE CHILLER FEATURES INCLUDE:

  • 30 Years Pool & Spa Experience
  • Excellent Engineering & Customer Support
  • Quality Assurance Backed By strong parts warranty
  • 5 year compressor warranty
  • Factory Tested To Customer Specification
  • Ship From Stock or Short Lead Times
  • Available with water cooled condensers
Cold Plunge & Spa Chillers Cold Pool by American Chillers

SPPC - Residential Series Cold Plunge Chillers – 1.5 to 10 tons

Cold Plunge Pool Chiller – for chlorine treated pools Description – Engineered for residential and light commercial usage

Models: Standard or Split chiller
Heat Exchanger Type – Stainless Steel, CuproNickel and Titanium
Warranty. 1 year parts and five year compressor limited warranty (see warranty policy)

Standard SPPC Features
· U.L. Listed, and EPA Compliant, R410a eco-friendly refrigeration complies with latest codes
· Single refrigeration circuit with separate and independent thermostat controls and safeties
· Air cooled, high ambient condensers for 100°F ambient
· Low ambient options for year around use in cold climates
· Suitable for outdoor installation (use “split model” in climates that freeze)
· Weather proof electrical panel with single point power connection
· Voltage and phase monitor protection (3 phase units)
· 24 vac control circuit with component sequenced terminal strip for easy troubleshooting
· Remote control panel with electronic thermostat, lighted push button on/off switches
· CuproNickel coaxial heat exchanger 
· Externally equalized thermal expansion valves with liquid line solenoid valves, filter driers, sight glasses
· Non ferrous water lines with FPT connections and insulated with 1/2” closed cell insulation
· Water flow safety switch locks out compressors on low flow to evaporator
· Freeze state safety helps protect evaporator from freezing
· Heavy welded steel frame with powder coated  corrosion protection
· Cabinet mounted chilled water supply pressure gauge
· Laminated cabinet panels with brushed aluminum finish
· Warranty: One ( 1 ) years limited parts, five ( 5 ) years limited compressor warranty

Options & Accessories (may affect cabinet dimension)
· Split system keeps hot air outdoors and water piping indoors (for locations with freezing temperatures)
· Castors for portability
· Factory authorized technician for start up, training & service
· Condenser coil coating for corrosion protection in coastal areas
· Titanium and stainless steel evaporators
· Other voltages and options available upon request
· Microprocessor controller for remote monitoring/control, timer and analytics
· Pumps installed or shipped loose

SPPC Warranty

Chiller Limited Parts Warranty

Covered Items: 1. All parts are guaranteed to be free of defects in material and workmanship for 12 months from date of original purchase. 2. Scroll compressors are guaranteed to be free of defects in material and workmanship for 60 months from date of purchase. 3. Labor: during the first 30 days after start up, American Chillers will reimburse the owner for any reasonable labor charges incurred for the replacement of a warranted part, according to the rate schedule.  A time allowance of 30 minutes, for one technician is allowed for the diagnosing of a malfunction. Consult customer service for the labor rate schedule. 4. During the first 30 days after start up, American Chillers will pay for regular, ground shipping of any covered part shipped to the customer. Express shipping and air freight charges are the responsibility of the customer. After 30 days, the customer is responsible for shipping defective parts back for credit and for the shipping charges from American Chillers to the customer.   Not Covered: 1. Shipping costs after the initial 30 days. Express shipping charges over regular ground charges are not covered. 2. Labor charges of a helper during repair; truck, mileage, and transportation charges; time over 30 minutes to diagnose a problem’s cause. 3. Labor rates in excess of pre-negotiated wholesale rates, usually no more than 70% of regular retail. American Chillers does not pay retail labor rates. 4. Loss of business or added expense for cranes, lifts, permits, or contractor services arising from the repair or replacement of a failed part. 5. Failures caused by external factors beyond the control of this manufacturer and the component manufacturer. 6. Supplies used to effect the repairs such as solder, nitrogen gas, dyes, bubble soap, and leak detector. 7. Part or component failure must be a result of manufacturing defect or normal wear and tear. Parts that fail due to causes external to the chiller, such as improper installation, electrical supply problems, leaking or broken pipes and tube erosion from excessive fluid velocity, freezing or poor water quality, failure to maintain clean filters, contractor or owner negligence, etc., are not covered by this warranty.  American Chillers will not reimburse the customer for locally purchased parts through another vendor without prior authorization. A replacement part, however, will be provided upon return of the defective part, only. 8. Electrical parts sent as replacement may not be returned for credit. 9. Glycol, replacement glycol, the labor to add glycol to the chiller and chiller damage resulting from improper freeze protection are not covered by the chiller warranty.   Policy Regarding Replacement Parts: American Chillers will provide a replacement part for any covered defective part as per the above conditions. Customers are responsible for shipping charges after the first 30 day period. Replacement parts may be new or reconditioned, at the discretion of American Chillers. All warranty claims must be processed through American Chillers.  The replacement part will be warranted for the remainder of the original part warranty or a minimum of 90 days.   Compressors: Compressors must have the connections securely plugged or pinched and soldered shut to prevent any oil, leakage during shipment. Failure to follow this procedure will void the warranty on the compressor. A $50.00 handling fee will be assessed for compressor warranty returns.   To Make a Warranty Claim  All warranty claims must be processed through American and all parts returned for credit must have a Return Material Authorization (RMA) number. To make a warranty claim, contact American Chillers between the hours of 8:00 a.m. – 4:30 p.m. (Eastern Time), Monday – Friday.  American Chillers will issue an RMA number. The RMA number must be clearly marked on the outside packaging or the package will be refused. Return parts must be packaged securely to avoid shipping damage. Parts damaged during shipment will not be credited.   Payment No parts will be shipped without payment. Parts must be paid for prior to shipment. American Chillers will accept VISA and MasterCard for your convenience. Your credit card will not be billed until the part(s) are shipped. Credit will be issued for the cost of the part, less any applicable freight and handling charges, after the defective part(s) are returned, freight prepaid, if the part failed due to a defect of material or workmanship. Return parts must be received within 30 days of making the claim. No credit or refunds will be given after 30 days.   The above information is correct for most purchases, however, warranty policies may vary by customer, equipment and/or job. Refer to your sales documents for warranty details specific to your purchase. Consult factory for any questions prior to ordering.

CPPC - Professional Series Cold Plunge Chillers – 1.5 to 10 tons

Cold Plunge Pool Chiller – for chlorine & salt water pools (specify when ordering)
Description – Engineered for commercial spa, therapy and sports facilities or with facilities where sound or  space requirements are restricted
Models. Available in single pass or with remote heat exchanger for outdoor installations
Heat Exchanger Type – Stainless Steel Brazed Plate Evaporator
Warranty. 2 year parts and five year compressor limited warranty (see warranty policy)

Standard Features
· The Ultra Quiet chillers is suitable for outdoor installation with 6” clearance
· Space saving Chiller can be wall mounted
· 16 ga. Galvanized steel cabinet with high gloss powder coat finish
· Cabinet mounted chilled water supply pressure and temperature gauges
· U.L. Listed, and EPA Compliant, R-404a refrigeration suitable for outdoors installation
· Copeland scroll compressor with crankcase heater and discharge safety thermostat
· Air cooled, high ambient, horizontal discharge condenser with EC high efficiency fan motor
· Receiver (12 lbs) with outlet shutoff valve and pressure safety
· Single point power connection into weather proof electrical panel
· Phase and voltage monitor guards against loss of phase, phase reversal
· 240 vac control circuit with digital, electronic thermostat, compressor anti, short-cycle time delay, water flow safety switch lockout, high and low refrigeration pressure safety lockout switches, compressor anti short-cycle timer
· Stainless steel nickel brazed evaporator with hot gas bypass capacity control
· Liquid line specialties include externally equalized thermal expansion valve with liquid line solenoid valve, filter drier, and sight glass
· Non-ferrous water lines with 1-1/4” FPT connections are wrapped in 1/2” closed cell insulation to prevent condensation
· System is factory leak checked, pressure tested, put under a deep vacuum, charged with refrigerant, and run tested under load prior to shipment
· The system and all parts are warranted to be free of manufactured defects for a period of thirteen (13) months from date of shipment

Options & Accessories
· Condenser coil coating for corrosion protection in coastal areas
· Split system refrigeration with condensing unit outdoors and chiller indoors
· Heated & insulated receiver in condensing unit for cold weather operation
· Full cabinet corrosion protection with 5 year warranty
· Marine grade chiller heat exchanger for salt water pools
· Factory authorized technician for startup and training
· Factory authorized contractor for installation
· Other voltages and options available; consult the factory 

CPPC Warranty

Chiller Limited Parts Warranty

Covered Items: 1. All parts are guaranteed to be free of defects in material and workmanship for 24 months from date of original purchase. 2. Scroll compressors are guaranteed to be free of defects in material and workmanship for 60 months from date of purchase. 3. Labor: during the first 30 days after startup, American Chillers will reimburse the owner for any reasonable labor charges incurred for the replacement of a warranted part, according to the rate schedule.  A time allowance of 30 minutes, for one technician is allowed for the diagnosing of a malfunction. Consult customer service for the labor rate schedule. 4. During the first 30 days after startup, American Chillers will pay for regular, ground shipping of any covered part shipped to the customer. Express shipping and air freight charges are the responsibility of the customer. After 30 days, the customer is responsible for shipping defective parts back for credit and for the shipping charges from American Chillers to the customer.   Not Covered: 1. Shipping costs after the initial 30 days. Express shipping charges over regular ground charges are not covered. 2. Labor charges of a helper during repair; truck, mileage, and transportation charges; time over 30 minutes to diagnose a problem’s cause. 3. Labor rates in excess of pre-negotiated wholesale rates, usually no more than 70% of regular retail. American Chillers does not pay retail labor rates. 4. Loss of business or added expense for cranes, lifts, permits, or contractor services arising from the repair or replacement of a failed part. 5. Failures caused by external factors beyond the control of this manufacturer and the component manufacturer. 6. Supplies used to effect the repairs such as solder, nitrogen gas, dyes, bubble soap, and leak detector. 7. Part or component failure must be a result of manufacturing defect or normal wear and tear. Parts that fail due to causes external to the chiller, such as improper installation, electrical supply problems, leaking or broken pipes and tube erosion from excessive fluid velocity, freezing or poor water quality, failure to maintain clean filters, contractor or owner negligence, etc., are not covered by this warranty.  American Chillers will not reimburse the customer for locally purchased parts through another vendor without prior authorization. A replacement part, however, will be provided upon return of the defective part, only. 8. Electrical parts sent as replacement may not be returned for credit. 9. Glycol, replacement glycol, the labor to add glycol to the chiller and chiller damage resulting from improper freeze protection are not covered by the chiller warranty.   Policy Regarding Replacement Parts: American Chillers will provide a replacement part for any covered defective part as per the above conditions. Customers are responsible for shipping charges after the first 30 day period. Replacement parts may be new or reconditioned, at the discretion of American Chillers. All warranty claims must be processed through American Chillers.  The replacement part will be warranted for the remainder of the original part warranty or a minimum of 90 days.   Compressors: Compressors must have the connections securely plugged or pinched and soldered shut to prevent any oil, leakage during shipment. Failure to follow this procedure will void the warranty on the compressor. A $50.00 handling fee will be assessed for compressor warranty returns.   To Make a Warranty Claim  All warranty claims must be processed through American and all parts returned for credit must have a Return Material Authorization (RMA) number. To make a warranty claim, contact American Chillers between the hours of 8:00 a.m. – 4:30 p.m. (Eastern Time), Monday – Friday.  American Chillers will issue an RMA number. The RMA number must be clearly marked on the outside packaging or the package will be refused. Return parts must be packaged securely to avoid shipping damage. Parts damaged during shipment will not be credited.   Payment No parts will be shipped without payment. Parts must be paid for prior to shipment. American Chillers will accept VISA and MasterCard for your convenience. Your credit card will not be billed until the part(s) are shipped. Credit will be issued for the cost of the part, less any applicable freight and handling charges, after the defective part(s) are returned, freight prepaid, if the part failed due to a defect of material or workmanship. Return parts must be received within 30 days of making the claim. No credit or refunds will be given after 30 days.   The above information is correct for most purchases, however, warranty policies may vary by customer, equipment and/or job. Refer to your sales documents for warranty details specific to your purchase. Consult factory for any questions prior to ordering.

COLD PLUNGE POOL CHILLER SIZING CHART

Cold Plunge Chiller Sizing Guide

Indoor Plunge Pool Chiller Sizing Guide 
Pool Volume (Gallons) Chiller Capacity  Chiller H.P @ 50F LWT Chiller H.P.  @ 45F LWT
100 to 300  1 Ton 1.0 1.5
300 to 450  1.5 Ton 1.5 2.0
450 to 650  2 Ton 2.0 2.5
650 to 950  3 Ton 3.0 3.5
950 to 1200  4 Ton 4.0 5.0
1,200 to 1,500  5 Ton 5.0 6.0
1,500 to 2,000 6 Ton 6.0 7.0
2,000 to 2,700  7 Ton 7.0 7.5
Above 2,700 C/F C/F C/F
Chiller Sizing Guide is based on the following: 1. Indoor pool in air-conditioned space. 2. Duration of use is short. 3. Dipping body part—not full body immersion.
Important considerations: 1. Piping that is exposed to sun light or not insulated. 2. Pools (like gunite) that are not insulated. 3. Direct sun light. 4. Pools that are open when not in use (not covered). 5. Warm ambient temperatures around pool. 6. High usage sites; like for a sports team, busy spa or therapy center. 7. Piping runs under warm cement floors. 8. Long piping runs (that can absorb heat). 9. Filter systems that add heat. 10. Cool down time – chart assumes chiller will be used to maintain the water at a fixed temperature. If chiller will be turned on/off with specified cool down times, consult factory.

Note – This is a guide only. No warranties or guaranties are given or implied. If site conditions are not consistent with chart limitations / conditions or if you are unsure about how to size, consult factory for assistance.

Cold Plunge Chiller Sizing Guide