DRY CLEANING CHILLERS

DRY CLEANING CHILLERS
Customized for Union, Realstar, Columbia, Multimatic, Firbimatic and more.

REQUEST INFORMATION

Dry Cleaning Chillers for Union, Firbimatic, Multimatic, Real Star and Columbia

Standard chillers in sizes 3-ton, 5-tons, 7.5-ton, 10-tons, 12.5-tons, 15-tons and 20-tons

  • Package Chillers: include tank, pump refrigeration all in one unit
  • Modular Chillers: outdoor chiller with indoor tank and pump. Tank and pumps ship loose for indoor installation.
  • Split Chillers: indoor chiller with outdoor condensing unit. Split chillers connect with refrigeration line sets.

For sizes over 20 tons, please contact our sales department

See also Cooling Towers For Dry Cleaning

  • Remote Controller with on-off switch, temperature controller and low flow indicator
  • Heavy duty welded, tubular steel frame with high gloss powder coat finish and laminated polyethylene cabinet
  • U.L. Listed, and EPA Compliant, eco-friendly R410a refrigeration condensing unit
  • Single refrigeration circuit with Copeland scroll compressor with crankcase heater
  • Air cooled, high ambient, vertical discharge, condensers for 100°F ambient with fan cycle low ambient control
  • Weatherproof electrical panel with single point power connection and 24 vac control circuit
  • Heavy duty tube in tube coaxial evaporator UL listed, and insulated with expanded foam
  • Auto reset low pressure safety; manual reset high pressure safety
  • Externally equalized thermal expansion valve, liquid line filter drier, and sight glass
  • Low water flow compressor interlock safety locks out compressors in low flow condition
  • Copper water lines with FPT connections insulated with 1/2” closed cell insulation
  • High density, polyethylene reservoir insulated with 1/2” closed cell insulation
  • High head centrifugal process pump rated at approximately 40 psi at 2.5 GPM/ton
  • Systems leak checked, pressure tested, run tested under load and shipped operation ready
  • Warranty: one (1) year limited parts, five (5) years limited compressor warranty
  • Condenser coil coating for corrosion protection in coastal areas
  • Fan speed control to maintain steady head pressure in cold ambient
  • Voltage and phase monitors
  • Cabinet mounted glycerin filled fluid supply pressure gauge
  • Cabinet mounted, glycerin filled refrigeration pressure gauges
  • Cabinet mounted, analog fluid inlet and outlet gauges
  • Inhibited propylene glycol concentrate for HVAC systems

How to Pipe Chillers in Parallel 

Two or more chillers may be installed in a parallel piping system to provide more capacity of a single chiller or redundancy and multi-staging of compressors. Normally the load on the chilled water system dictates the system capacity and the part load capacity of the process is the factor to determine the staging of the chillers on temperature. The thermostats can be set a few degrees apart. If one chiller cannot maintain the fluid temperature, the second chiller will stage on upon temperature rise and a third, etc.

The diagram below illustrates the concept of parallel piping of the chillers on a common header system. The main header must be sized for the total flow rate and good practices dictates a maximum flow rate of 7 Ft/sec.

When adding a chiller to an existing manifold system, also consider the ability of the pump to provide enough total flow and pressure to satisfy the process and the continuous flow through the chillers.  Nominal flow rate for commercial equipment of 2.5 GPM / on are normally a minimum with 70 to 100 ft. hd. (30 psi to 43 psi) capability. Contact American Chillers engineers for assistance.

Dry Cleaning Chiller Installation
Installing A Bypass Loop

Purpose:

  1. To provide a continuously circulating water flow through the chiller coil, tank and piping system. This is necessary to maintain the reservoir at the cold temperature setting. The system should be balanced so that the flow through the bypass loop while maintaining sufficient flow to the process.
  2. To establish the minimum operating pressure of the cooling water supply to the process machine. This is a result of setting the continuous flow at maximum. This also establishes a high-pressure supply to the process machine and a low pressure return to the chiller for good circulation through the process machine heat exchangers. The differential pressure between the supply and return should be a minimum of 20 psi.
  3. To allow the chiller refrigeration to cycle on and off freely, and independently of external demands for flow and temperature.

Where To Put the Bypass:

The bypass valve must be located at the end of the line, with the process machine connections between the bypass and the pump.

The illustration below shows a modular chiller system with the process (dry cleaning) machine correctly connected to the piping between the pump and the bypass.

The pressure to the process machine (s) will be the same every inch in the line between the bypass and the pump. Two machines can be connected, and their supply pressure will be the same.

The picture shows the bypass before the process machine connections and the pressure will be lower to the machine when the bypass is open. The drop in pressure will increase as the bypass is opened and set for optimum flow to the chiller. The process machine heat exchangers very likely will starve for cooling as a result.

This photo clearly shows the wrong way to connect the bypass. The natural tendency of the operator when the process machine alarms due to lack of cold water is to close the bypass to force more pressure and flow to the process machine heat exchangers.

Starving the Chiller:

The process machine will get more pressure and flow as a result of closing the bypass – But what happens to the chiller?

The chiller will starve for flow causing the water temperature to be very cold coming out of the chiller but at a reduced flow that will cause the loop temperature to swing wildly between cold and hot! The purpose of the flowing loop has been defeated and the chiller cannot maintain the reservoir and loop temperature at an even temperature. The temperature fluctuations of the water supply can be 30 to 40 degrees or more.

Bypass Line Size:

The piping connections on the chiller are the correct size for the supply and return header lines based on sound engineering principles of flow, pressure drops, and fluid velocity. Reducing the line size from the recommended causes higher velocities, higher pressure drops, reduced supply pressure to the process machine, and fluctuations in the supply temperature.

WHY USE GLYCOL

A chiller will run without glycol as long as the fluid temperature in the system is above freezing. Glycol or other inhibitors are recommended for most process cooling applications even if the fluid temperature doesn’t reach temperatures near freezing to maintain fluid quality.

Which of glycol is best?
Inhibited Propylene Glycol is recommended. It works as an anti-freeze and contains rust inhibitors and other additives to keep your pump seals lubricated and fluids and chilled water system running in optimal condition. It is also deemed food and environmentally friendly.

NEVER USE AUTOMOTIVE OR RV ANIT-FREEZE IN CHILLERS. THEY BREAK DOWN AND WILL DAMAGE YOUR CHILLER AND DRY-CLEANING EQUIPMENT.

Glycol will reduce chiller capacity if the evaporator isn’t size for it. Our dry-cleaning chillers are sized for 40% PPG / 60% Water.

Questions about what glycol concentration and/or type to purchase? Contact and American Chillers sales engineer for assistance.

Glycol Correction Factors

All Heat exchangers experience a capacity loss when the fluid is a higher specific gravity than water. Glycols are heavy, syrup like fluids at full concentration, and become thinner when mixed with water. However, the mixed solution of water-glycol will be thicker, heavier, than the water alone was. Thus, to achieve the same heat exchange inside the heat exchanger , requires more surface area or a larger heat exchanger.

American Chillers heat exchangers are engineered for full rated capacity with the use of 30% glycol solutions. Our heat exchangers start out with 30% more surface area capacity than the heat exchangers used by other manufacturers so you still have full capacity with 30% water-glycol solutions. If you are using glycol concentrations above 30%, consult factory prior to purchasing your chiller for chiller selection assistance.

Propylene Glycol

Leaving Temperature Degrees F 30% 40% 50%
Capacity
Factor
Pressure
Drop Factor
Capacity
Factor
Pressure
Drop Factor
Capacity
Factor
Pressure Drop
Factor
20 0,8 1,74 0,74 2,07
30 0,92 1,39 0,87 1,63 0,82 1,94
40 0,93 1,36 0,89 1,55 0,85 1,83
45 0,94 1,35 0,9 1,53 0,87 1,81
50 0,94 1,33 0,91 1,51 0,88 1,75
55 0,95 1,31 0,92 1,5 0,89 1,73
60 0,95 1,31 0,92 1,47 0,9 1,68
70 0,96 1,27 0,93 1,43 0,91 1,63
Minimum leaving fluid temperature 25°F 10°F -10°F
Minimum ambient 10°F -4°F -20°F

 

Ethylene Glycol

Leaving Temperature Degrees F 30% 40% 50%
Capacity
Factor
Pressure
Drop Factor
Capacity
Factor
Pressure
Drop Factor
Capacity
Factor
Pressure Drop
Factor
20 0,92 1,39 0,89 1,61 0,86 1,86
30 0,96 1,34 0,93 1,53 0,9 1,78
40 0,96 1,33 0,94 1,52 0,92 1,74
45 0,96 1,33 0,94 1,51 0,93 1,72
50 0,96 1,31 0,95 1,49 0,93 1,69
55 0,96 1,31 0,95 1,47 0,94 1,67
60 0,97 1,31 0,96 1,47 0,94 1,65
70 0,97 1,27 0,96 1,49 0,95 1,62
Minimum leaving fluid temperature 20°F 5°F -15°F
Minimum ambients 5°F -9°F -28°F

 

Glycol Capacities and Correction Tables


* At standard ARI 590 conditions: 54°F entering fluid temperature, 44°F leaving fluid temperature, 95°F ambient temperature, 0.0005 fouling

The charts, above, illustrate the differences between propylene based and ethylene based glycol. Since we recommend propylene based glycols because of their non-hazardous nature, we must be aware of the effects on the standard refrigeration heat exchangers and pumps.

A 40% solution of propylene glycol will reduce the chiller heat exchanger’s ability to chill by at least 7.2%. We know from experience, that some heat exchangers chilling abilities is reduced by 20%. This means the chiller with a 10 ton capacity for chilling water will have a capacity between 8 tons and 9.3 tons with 40% PG.

Most American Chillers have heat exchangers large enough to handle 30% PG without loss of capacity due to our “value-added” engineering practices. We can easily provide a chiller heat exchanger for even 50% PG at the customer request at time of order.

 

What Is Covered:

  1. All parts are guaranteed to be free of defects in material and workmanship for 12 months from date of original purchase.
  2. Scroll compressors are guaranteed to be free of defects in material and workmanship for 60 months from date of purchase.
  3. Labor: during the first 30 days after startup, American Chillers will reimburse the owner for any reasonable labor charges incurred for the replacement of a warranted defective part, according to the rate schedule.  A time allowance of 30 minutes, for one technician is allowed for the diagnosing of a malfunction. Consult customer service for the labor rate schedule.
  4. During the first 30 days after startup, American Chillers will pay for regular, ground shipping of any covered part shipped to
    the customer. Express shipping and air freight charges are the responsibility of the customer. After 30 days, the customer is responsible for shipping defective parts back for credit and for the shipping charges from American Chillers to the customer.

What is not covered:

  1. Shipping costs after the initial 30 days. Express shipping charges over regular ground charges are not covered.
  2. Labor charges of a helper during repair; truck, mileage, and transportation charges; time over 30 minutes to diagnose a problem’s cause.
  3. Labor rates in excess of pre-negotiated wholesale rates, usually no more than 70% of regular retail. American Chillers does not pay retail labor rates.
  4. Loss of business or added expense for cranes, lifts, permits, or contractor services arising from the repair or replacement of a failed part.
  5. Failures caused by external factors beyond the control of this manufacturer and the component manufacturer.
  6. Supplies used to affect the repairs such as solder, nitrogen gas, dyes, bubble soap, and leak detector.
  7. Part or component failure must be a result of manufacturing defect or normal wear and tear. Parts that fail due to causes external to the chiller, such as improper installation, electrical supply problems, leaking or broken pipes and tube erosion from excessive fluid velocity, freezing or poor water quality, failure to maintain clean filters, contractor or owner negligence, etc., are not covered by this warranty.  American Chillers will not reimburse the customer for locally purchased parts through another vendor without prior authorization. A replacement part, however, will be provided upon return of the defective part, only.
  8. Electrical parts sent as replacement may not be returned for credit.
  9. Glycol, replacement glycol, the labor to add glycol to the chiller and chiller damage resulting from improper freeze protection are not covered by the chiller warranty.

Policy Regarding Replacement Parts:

American Chillers will provide a replacement part for any covered defective part as per the above conditions. Customers are responsible for shipping charges after the first 30 day period. Replacement parts may be new or reconditioned, at the discretion of American Chillers. All warranty claims must be processed through American Chillers.  The replacement part will be warranted for the remainder of the original part warranty or a minimum of 90 days.

Compressors:

Compressors must have the connections securely plugged or pinched and soldered shut to prevent any oil, leakage during shipment. Failure to follow this procedure will void the warranty on the compressor. A $50.00 handling fee will be assessed for compressor warranty returns.

To Make a Warranty Claim 

All warranty claims must be processed through American Chillers, and all parts returned for credit must have a Return Material Authorization (RMA) number. To make a warranty claim, contact American Chillers between the hours of 8:00 a.m. – 4:30 p.m. (Eastern time), Monday – Friday.  American Chillers will issue an RMA number. The RMA number must be clearly marked on the outside packaging, or the package may be refused. Return parts must be packaged securely to avoid shipping damage. Parts damaged during shipment will not be credited.